BAM High Voltage Power Capacitor
Fampiharana sy fenitra:
Ny capacitor avo lenta dia ampiasaina indrindra amin'ny rafitra AC Power miaraka amin'ny 50Hz mba hanatsarana ny hery. Ny fampisehoana dia mifanaraka amin'ny GB 3083.2-89 《Kapasitera shunt avo lenta》ary IEC60871-1987.
GB / T11024-2010 fenitra nasionaly 《Voatanisa 1kV na ambony shunt capacitors ho an'ny rafitra herinaratra AC
JB/7112-2000 Fitsipika indostrian'ny milina 《Vorona HV Shunt Capacitor
DL/T628-1997 Fenitry ny indostrian'ny herinaratra 《Namboarina HV Shunt Capacitor baiko fepetra ara-teknika》
Fepetra fampiasana:
1.Altitude: latsaky ny 1000m; Ambient mari-pana: -40 ℃ ~ + 40 ℃.
2. Tsy misy vibration mekanika mahery vaika, tsy misy entona sy etona manimba, tsy misy herinaratra, ary vovoka mipoaka ary mipoaka eo amin'ny toerana.
3. Volavolan'ny asa mitohy: 1.00 Un, max maharitra, Volavony mihoatra: latsaka.1 Un.
4. Mihoatra noho ny stable (anisan'izany ny harmonic current) latsaky ny 1.3 In.
5. Miaraka amin'ny voltase mijoro: eo anelanelan'ny terminal 2.15, ny volavolan-dalàna amin'ny 10 segondra, eo anelanelan'ny terminal sy ny container 42kV mandritra ny 10 segondra.
Toetra ara-teknika lehibe:
1. Volavolan'ny naoty: 6.3kV, 6.6kV, 6.6/√3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11/√3kV, azafady aseho ao amin'ny filaharana raha tianao ny fahafahana manokana hafa.
2.Rated fahafahana: 33~334kvar azafady aseho ao amin'ny filaharana raha tianao ny hafa fahaiza-manao manokana.
3. Fahaizana fandeferana: -5 ~ 15%.
4. Loss angel tangential sanda: sarimihetsika & papaer antonony tg θ≦0.08%, sarimihetsika antonony tg θ≦0.05%.
5. Mahazaka malefaka: afaka mahazo AC2.15 na DC4.3 fotoana naoty malefaka eo amin'ny fahaiza-manao pales, farany eo amin'ny 10s tsy misy fiatoana na tselatra, BIL: 6kV(30kV), 10kV(42Kv).
6.Free discharge: manana ny fanoherana anatiny, 10min aorian'ny fanapahana ny famatsiana herinaratra, ny sisa tavela dia hihena ho 75V avy amin'ny √2 Un.
7. Max. Amin'izao fotoana izao: mandeha tsara eo ambanin'ny 1.3 fotoana voamarika malefaka, overvoltage, fahaiza-manao fandeferana tsara ary onja harmonika izay tsy mihoatra ny 1 min isaky ny 24 ora.
8.Max.Current: mandeha tsara eo ambanin'ny fe-potoana 1.3 naoty malefaka, overvoltage, fandeferana tsara ary onja harmonic izay tsy afaka 1.43 amin'izao fotoana izao.
9. Fenitra: GB/T 112024.1-2001, IEC6087:1997.
CAPASITOR HERIN-KEVITRA MIARAKA
MODELY BAM | Voltage naoty (kV) | Output naoty (kVAr) | Fahaizana naoty (uF) | Naoty amin'izao fotoana izao (A) |
6.3-25-1W | 6.3 | 25 | 2.006 | 3.968 |
6.3-30-1W | 6.3 | 30 | 2.406 | 4.762 |
6.6/√3-25-1W | 6.6/√3 | 25 | 5.481 | 6.561 |
6.3/√3-30-1W | 6.6/√3 | 30 | 6.577 | 7.873 |
6.3/√3-50-1W | 6.6/√3 | 50 | 10.96 | 13.12 |
10.5-25-1W | 10.5 | 25 | 0.722 | 2.38 |
10.5-30-1W | 10.5 | 30 | 0.886 | 2.857 |
10.5-50-1W | 10.5 | 50 | 1.444 | 4.762 |
11/√3-30-1W | 11/√3 | 30 | 2.368 | 4.724 |
11/√3-50-1W | 11/√3 | 50 | 3.946 | 7.873 |
6.3-30-1W | 6.3 | 30 | 2.4 | 4.76 |
6.3-50-1W | 6.3 | 50 | 4 | 7.9 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | efatra amby roapolo | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
10.5-50-1W | 10.5 | 50 | 1.44 | 4.8 |
10.5-100-1W | 10.5 | 100 | 2.9 | 9.5 |
10.5-150-1W | 10.5 | 150 | 4.3 | 14.3 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-300-1W | 10.5 | 300 | 8.67 | 28.6 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |
11/√3-50-1W | 11/√3 | 50 | 3.95 | 7.87 |
11/√3-100-1W | 11/√3 | 100 | 7.89 | 15.75 |
11/√3-150-1W | 11/√3 | 150 | 11.84 | 23.6 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-300-1W | 11/√3 | 300 | 23.68 | 47.2 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
6.6/√3-50-1W | 6.6/√3 | 50 | 10.96 | 13.12 |
6.6/√3-100-1W | 6.6/√3 | 100 | 21.9 | 26.24 |
6.6/√3-150-1W | 6.6/√3 | 150 | 32.9 | 39.36 |
6.6/√3-200-1W | 6.6/√3 | 200 | 43.8 | 52.48 |
6.6/√3-300-1W | 6.6/√3 | 300 | 65.8 | 78.7 |
6.6/√3-334-1W | 6.6/√3 | 334 | 73.2 | 87.6 |
11-100-1W | 11 | 100 | 2.63 | 9.1 |
11-150-1W | 11 | 150 | 3.95 | 13.6 |
11-200-1W | 11 | 200 | 5.26 | 18.2 |
11-300-1W | 11 | 300 | 7.89 | 27.3 |
11-334-1W | 11 | 334 | 8.79 | 30.4 |
12-100-1W | 12 | 100 | 2.2 | 8.33 |
12-150-1W | 12 | 150 | 3.3 | 12.5 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-300-1W | 12 | 300 | 6.64 | 25 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
12/√3-100-1W | 12/√3 | 100 | 6.63 | 14.4 |
12/√3-150-1W | 12/√3 | 150 | 9.95 | 21.7 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-300-1W | 12/√3 | 300 | 19.9 | 43.3 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12/√3-400-1W | 12/√3 | 400 | 26.54 | 57.74 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-150-1W | 6.3 | 150 | 12 | 23.8 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | efatra amby roapolo | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
6.6-100-1W | 6.6 | 100 | 7.3 | 15.2 |
6.6-150-1W | 6.6 | 150 | 11 | 22.7 |
6.6-200-1W | 6.6 | 200 | 14.6 | 30.3 |
6.6-300-1W | 6.6 | 300 | roa amby roampolo | 45.5 |
6.6-334-1W | 6.6 | 334 | 24.4 | 50.6 |
6.6/√3-100-1W | 6.6/√3 | 100 | 21.9 | 26.24 |
6.6/√3-150-1W | 6.6/√3 | 150 | 32.9 | 39.36 |
6.6/√3-200-1W | 6.6/√3 | 200 | 43.8 | 52.48 |
6.6/√3-300-1W | 6.6/√3 | 300 | 65.8 | 78.7 |
6.6/√3-334-1W | 6.6/√3 | 334 | 73.2 | 87.6 |
11/√3-100-1W | 11/√3 | 100 | 7.89 | 15.75 |
11/√3-150-1W | 11/√3 | 150 | 11.84 | 23.6 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-300-1W | 11/√3 | 300 | 23.68 | 47.2 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.3 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.2 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |